arXiv ScienceSearch

arXiv · 1505.07085

The SST Fully-Synchronous Multi-GHz Analog Waveform Recorder with Nyquist-Rate Bandwidth and Flexible Trigger Capabilities

Abstract

The design and performance of a fully-synchronous multi-GHz analog transient waveform recorder I.C. ("SST") with fast and flexible trigger capabilities is presented. The SST's objective is to provide multi-GHz sample rates with intrinsically-stable timing, Nyquist-rate sampling and high trigger bandwidth, wide dynamic range and simple operation. Containing 4 channels of 256 samples per channel, the SST is fabricated in an inexpensive 0.25 micrometer CMOS process and uses a high-performance package that is 8 mm on a side. It has a 1.9V input range on a 2.5V supply, exceeds 12 bits of dynamic range, and uses ~128 mW while operating at 2 G-samples/s and full trigger rates. With a standard 50 Ohm input source, the SST exceeds ~1.5 GHz -3 dB bandwidth. The SST's internal sample clocks are generated synchronously via a shift register driven by an external LVDS oscillator running at half the sample rate (e.g., a 1 GHz oscillator yields 2 G-samples/s). Because of its purely-digital synchronous nature, the SST has ps-level timing uniformity that is independent of sample frequencies spanning over 6 orders of magnitude: from under 2 kHz to over 2 GHz. Only three active control lines are necessary for operation: Reset, Start/Stop and Read-Clock. When operating as common-stop device, the time of the stop, modulo 256 relative to the start, is read out along with the sampled signal values. Each of the four channels integrates dual-threshold trigger circuitry with windowed coincidence features. Channels can discriminate signals with ~1mV RMS resolution at >600 MHz bandwidth.

Explore related subjects

Keep this discovery

BibTeXRIS

Stuart A. Kleinfelder, Edwin Chiem, Tarun Prakash. 2015-05-26. The SST Fully-Synchronous Multi-GHz Analog Waveform Recorder with Nyquist-Rate Bandwidth and Flexible Trigger Capabilities. https://doi.org/10.1109/nssmic.2014.7431232

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

High-Speed Semi-FE Readout Module for ATLAS MDT at HL-LHC: Design and Production-Level Characterization

The High-Luminosity upgrade of the Large Hadron Collider (HL-LHC) introduces increased demands on the ATLAS Muon Spectrometer, particularly in terms of data throughput, timing distribution and system reliability. The Phase-II Chamber Service Module (CSM) is a key component of the upgraded Monitored Drift Tube (MDT) trigger and readout system, providing a high-speed interface between the front-end electronics and the backend systems. This paper describes the design and implementation of the Phase-II CSM, together with its validation. The results show that the CSM supports two independent optical uplinks, each operating at a line rate of 10.24 Gbps, together with clock distribution and slow control in the expected operating environment. Integration with small-diameter MDT (sMDT) chambers and tests with the prototype L0MDT trigger system are also presented. The CSM boards are now in production and will be used for installation and integration during the upcoming LHC Long Shutdown.

physics.ins-det

Spectral Discrimination of Deposited Gamma-Ray Energies in a Simulated CeBr$_3$ Scintillator

We show that wavelength measurements of individual detected optical photons may provide additional information about gamma-ray energy deposited in a CeBr$_3$ crystal when the detected-photon-count distributions overlap for nearby gamma-ray energies. Monoenergetic 662 and 629 keV gammas are used in a Geant4 simulation of a $25\times25\times20~\mathrm{mm^3}$ CeBr$_3$ crystal. Assuming a light yield of $6.0\times10^4$ photons/MeV, a wavelength-independent photon-detection efficiency of 30%, and a wavelength resolution of $\sigma_{\lambda}=40$ nm, we find that the fraction of photons reconstructed above 385 nm gives an event-level separation of $\sim$ 2 standard deviations between the 662 and 629 keV event populations selected within the same $\sim$ 1%-wide detected-photon-count interval. No timing or reconstructed interaction-position information is used. The result demonstrates, within the present simulation model, that event-dependent optical spectra can retain energy information beyond an undifferentiated photon count.

physics.ins-det

Operation of a negative ion gas time projection chamber without electronegative fill gases

The high fidelity reconstruction of particle tracks in micropatterned gaseous time projection chambers renders this technology ideal for future rare-event searches, including direction-sensitive dark matter experiments. Large drift distances are typically required for such experiments, so that the overall spatial resolution is limited by diffusion. Negative ion drift exhibits lower diffusion than electron drift and is thus an attractive option for realising a large-scale detector. The use of electronegative gases to create negative ions introduces technical challenges, most notably a reduction in gain when compared to conventional gas mixtures. In this study, we demonstrate a new method for negative ion generation via dissociative electron attachment using the conventional molecular fill gas CF$_4$. Our optical measurements of negative ion drift indicate electron attachment lengths of $<$1 mm and comparable gain to electron avalanches. The individual negative ion avalanches were also time-resolved, allowing the number of ions reaching the readout to be counted. We measure an improved energy resolution by single ion counting, relative to an integrated electron avalanche signal measured under identical gain conditions.

physics.ins-det