Fundamental limitations to high-precision tests of the universality of free fall by dropping atoms

Abstract

Tests of the universality of free fall and the weak equivalence principle probe the foundations of General Relativity. Evidence of a violation may lead to the discovery of a new force. The best torsion balance experiments have ruled it out to 10^-13. Cold-atom drop tests have reached 10^-7 and promise to do 7 to 10 orders of magnitude better, on the ground or in space. They are limited by the random shot noise, which depends on the number N of atoms in the clouds. As mass-dropping experiments in the non-uniform gravitational field of Earth, they are sensitive to the initial conditions. Random accelerations due to initial condition errors of the clouds are designed to be at the same level as shot noise, so that they can be reduced with the number of drops along with it. This sets the requirements for the initial position and velocity spreads of the clouds with given N. In the STE-QUEST space mission proposal aiming at 2x10^-15 they must be about a factor 8 above Heisenberg's principle limit, and the integration time required to reduce both errors is 3 years, with a mission duration of 5 years. Instead, offset errors at release between different atom clouds are systematic and give rise to a systematic effect which mimics a violation. Such offsets must be demonstrated to be as small as required in all drops, must be small by design and must be measured. For STE-QUEST to meet its goal they must be several orders of magnitude smaller than the size of each individual cloud, which in its turn must be at most 8 times larger than the uncertainty principle limit. Even if all technical problems are solved and the clouds are released with negligible systematic errors, still they must be measured. Then, Heisenberg's principle dictates that the measurement lasts as long as the experiment and the systematic nature of the effect requires many measurements for it to be ruled out as a source of violation.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Anna M. Nobili. 2016-01-25. Fundamental limitations to high-precision tests of the universality of free fall by dropping atoms. https://doi.org/10.1103/physreva.93.023617

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Mortality of ultra-thin LGADs and PiN diodes from high energy deposition

Low Gain Avalanche Diodes are prime candidates for high-resolution timing applications in High Energy Physics, Nuclear science, and several other fields. Operating these devices in high-radiation environments presents various hazards, including the risk of their permanent degradation or destruction caused by effects such as Single Event Burnout. Studies using minimum ionizing particles found a greatly reduced Single Event Burnout risk by operating below a bias voltage corresponding to an average electric field of 12 V/$μ$m - however, as high energy particle colliders produce a wide energy spectrum of radiation, it is crucial to understand this phenomenon and other possible damage mechanisms at energy deposition levels greater than those of minimum ionizing particles. This was achieved by pre-irradiating LGADs and PiN diodes with active thicknesses of 20, 30, and 50 $μ$m up to 1.5 $\times$ 10$^{15}$ $\mathrm{n_{eq}/cm^2}$, and exposing them to beams of protons and heavy ions (C, O, Fe, Au) at the BNL Tandem van de Graaff accelerator. Several mortality categories were observed, defined by different electrical and mechanical damage signatures. This furthers our understanding of permanent radiation damage of silicon devices, crucial towards mitigating Single Event Burnout and other damage mechanisms to safely operate future detectors.

physics.ins-det

Small but Tubby: A Magnetic Loop Antenna Made from 100 mm Copper Tubing

This paper presents the electrical model, key equations, and practical construction of a small transmitting magnetic loop antenna built from unusually large 100 mm diameter copper tubing. The large conductor surface area and wide-area transitions to the vacuum capacitors were designed to minimize resistive losses. The frequency range from 1.8 MHz to 31 MHz is unusually wide. Frequency, impedance matching, and azimuth are all adjusted automatically by servo motors. Indoor losses originate predominantly from near-field coupling to the environment rather than from the antenna itself. Temperature-rise measurements confirm that the bulk of the dissipated power is absorbed by the environment, not by the antenna components. The conducted H-field measurements demonstrate good agreement between the measured H-field and the theoretical free-space H-field calculated from the antenna geometry and an estimated loop current. The loop current was estimated from the measured antenna bandwidth and the applied transmit power. The antenna was developed for indoor operation where outdoor installation is not possible.

physics.ins-det

Construction and characterisation of the DarkSide-20k veto silicon photo-multiplier tiles

Silicon photo-multipliers (SiPMs) are state-of-the-art sensors capable of detecting a single photoelectron under cryogenic conditions, with potentially lower radioactivity than widely used photomultiplier tubes. The DarkSide-20k experiment, designed to perform direct dark matter searches using liquid argon as the target material, employs SiPM technology to detect interactions in the active detector volumes, including the central dual-phase Time Projection Chamber and the Inner and Outer Veto volumes. The vetoes are designed to discriminate against radiogenic neutron and cosmic muon backgrounds associated with the dark matter search. This paper describes the completed production and test protocols for the "Veto Tiles" (called vTiles, arrays of 24 SiPMs integrated on a printed circuit board providing the power distribution and signal amplification); 16 vTiles are grouped into "Veto Photo-Detector Units" to instrument the Inner Veto volume. Each vTile underwent detailed testing at room and cryogenic temperatures, confirming stable operation, high signal-to-noise ratio, and low radioactive contamination, demonstrating the robustness of the proposed design for cryogenic conditions. The final production yield exceeded 87%, surpassing the 80% requirement and corresponding to 1920 Veto Tiles to populate 120 Veto Photo-Detector Units, plus an additional 6% as spares.

physics.ins-det