arXiv ScienceSearch

arXiv · 1501.05521

Random Number Hardware Generator Using Geiger-Mode Avalanche Photo Detector

Abstract

This paper presents the physical concept and test results of sample data of the high-speed hardware true random number generator design based on typically used for High Energy Physics hardware. Main features of this concept are the high speed of the true random numbers generation (tens of Mbt/s), miniature size and estimated lower production cost. This allows the use of such a device not only in large companies and government offices but for the end-user data cryptography, in classrooms, in scientific Monte-Carlo simulations, computer games and any other place where large number of true random numbers is required. The physics of the operations principle of using a Geiger-mode avalanche photo detector is discussed and the high quality of the data collected is demonstrated.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D. Beznosko, T. Beremkulov, A. Duspayev, A. Iakovlev, A. Tailakov, M. Yessenov. 2016-11-17. Random Number Hardware Generator Using Geiger-Mode Avalanche Photo Detector. https://arxiv.org/abs/1501.05521

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Design, construction, and initial operation of a 30-ton Water-based Liquid scintillator detector at Brookhaven National Laboratory

Water-based Liquid Scintillator (WbLS) was proposed over a decade ago as a novel detector medium that might allow the separation and tuning of the relative ratio of the Cherenkov and scintillation signals. A detector employing this technology could support large-scale neutrino detection over both the GeV and MeV energy regimes, while its metal-loading capability could provide an effective means of neutron tagging. WbLS is attractive for two reasons. It can be deployed in very large detectors. It also allows in-situ tuning of the scintillator concentration, and hence the ratio of Cherenkov to scintillation light. Neither pure water Cherenkov detectors nor conventional liquid scintillator detectors offer this capability. At Brookhaven National Laboratory (BNL), two prototypes have been built for understanding WbLS properties and stability, with masses of 1-ton and 30-ton, respectively. We present here the 30-ton prototype detector design, installation, and initial operation including the real-time observation of a transient optical response during the staged scintillator injection. Results from the analysis of data collected in the two detectors will follow in separate publications.

physics.ins-det

Constraint-Traceable Liquid-Nitrogen Dewar Design for Low-Noise HTS-SQUID Magnetometry

Compact high-temperature superconducting quantum interference device (HTS-SQUID) magnetometers require a liquid-nitrogen Dewar that balances operating duration against instrument-envelope and mass constraints. Here we introduced a constraint-traceable design workflow in which body radius and neck-length fraction were scanned under fixed outer-envelope volume and geometry-based mass limits. The longest-duration feasible grid point lay adjacent to the 3.85 kg and 550 mm constraint intersection, predicting 224 h hold time from a body-only initial fill to a residual liquid depth of 10 mm. A reference Dewar was experimentally monitored for 137.3 h, consuming 1.22 L liquid-nitrogen of its initial inventory. A thermal model calibrated over the first 40 h reproduced the remaining 97.3 h. Device measurements at liquid-nitrogen temperature showed a superconducting transition and Fraunhofer-like junction response, a maximum voltage-modulation depth of 36.2 $μ$V, and a median noise level of 41.5 fT Hz$^{-1/2}$ from 100 to 1000 Hz. These results establish a reproducible method for selecting Dewar geometry under coupled constraints and demonstrate compatibility with long-endurance and low-noise HTS-SQUID magnetometer systems.

physics.ins-det

Decay-Resolved Charge Changes from Radioactive Decays in Levitated Microparticles

We measure event-by-event discrete changes in the net electric charge of an optically levitated silica microsphere arising from individual radioactive decays within the sphere, in coincidence with energy depositions in a nearby scintillation detector. The net charge of the levitated sphere is continuously monitored by measuring its driven response to an oscillating electric field, allowing individual charge-change events to be resolved on millisecond timescales with precision below an elementary charge. Simultaneously, $α$ and $β$ particles emitted during decays of implanted $^{212}$Pb and its daughters are detected using a scintillator read out with an array of silicon photomultipliers. By correlating reconstructed charge-change times with the scintillator response, we can directly attribute abrupt changes in the sphere's net charge to individual nuclear decays, and identify differences in the distribution of charges ejected for $α$ and $β$ decays. These results establish a new approach for studying low energy charged particles emitted by radioactive decays at the single-decay level, and identify showers of radiogenically produced low-energy electrons emitted by $α$-decaying radon daughters implanted near solid surfaces.

physics.ins-det