arXiv ScienceSearch

arXiv · 1411.4120

The neutron-gamma Feynman variance to mean approach: gamma detection and total neutron-gamma detection (theory and practice)

Abstract

Two versions of the neutron-gamma variance to mean (Feynman-alpha method or Feynman-Y function) formula for either gamma detection only or total neutron-gamma detection, respectively, are derived and compared in this paper. The new formulas have a particular importance for detectors of either gamma photons or detectors sensitive to both neutron and gamma radiation. If applied to a plastic or liquid scintillation detector, the total neutron-gamma detection Feynman-Y expression corresponds to a situation where no discrimination is made between neutrons and gamma particles. The gamma variance to mean formulas are useful when a detector of only gamma radiation is used or when working with a combined neutron-gamma detector at high count rates. The theoretical derivation is based on the Chapman-Kolmogorov equation with inclusion of general reactions and passage intensities for neutrons and gammas, but with the inclusion of prompt reactions only. A one energy group approximation is considered. The comparison of the two different theories is made by using reaction intensities obtained in MCNPX simulations with a simplified geometry for two scintillation detectors and a 252Cf-source enclosed in a steel container. In addition, the variance to mean ratios, neutron, gamma and total neutron-gamma, are evaluated experimentally for a weak 252Cf neutron-gamma source in a steel container, a 137Cs random gamma source and a 22Na correlated gamma source. Due to the focus being on the possibility of using neutron-gamma variance to mean theories for both reactor and safeguards applications, we limited the present study to the general analytical expressions for Feynman-Y formulas.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Dina Chernikova, Kåre Axell, Senada Avdic, Imre Pázsit, Anders Nordlund. 2015-01-23. The neutron-gamma Feynman variance to mean approach: gamma detection and total neutron-gamma detection (theory and practice). https://doi.org/10.1016/j.nima.2015.01.104

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Reinvestigation of the Yield of the Trinity Device

Previous published analyses of trinitite to determine the yield of the Trinity nuclear explosion used various estimates of the fraction of fission products that became incorporated in trinitite. Furthermore, these studies utilized nuclear data that has subsequently been revised. Utilizing a planar germanium detector, we observed gamma rays produced by the decays of both 137Cs and 239Pu from four samples of trinitite. From the observed 137Cs/239Pu ratios of and a simple analysis method based on current nuclear data and weapons debris studies, we find an average yield of 9.1+-4.5 kilotons from our four samples. While this result is substantially lower than the established total yield of 21 kilotons, it is in reasonable agreement that attributable to fissions in the 239Pu core alone.

nucl-ex

Search for neutrinoless quadruple beta decay of $^{136}$Xe in PandaX-4T detector

The observation of neutrinoless quadruple beta decay (0$\nu$4$\beta$) in the absence of neutrinoless double beta decay (0$\nu$2$\beta$) has been argued to provide a strong indication that neutrinos are Dirac particles. We report a search for 0$\nu$4$\beta$ decay of $^{136}\text{Xe}$ using a total $^{136}\text{Xe}$ exposure of 148.4 kg$\cdot$yr, collected during the commissioning and the first science runs of the PandaX-4T experiment. No significant excess of events over the background is observed. A lower limit on the 0$\nu$4$\beta$ decay half-life of $^{136}\text{Xe}$ is set at 6.01 x $10^{24}$ yr at the 90% confidence level. This result establishes the most stringent constraint on this process in xenon, demonstrating the unique capability of the PandaX-4T detector in probing lepton number violation and shedding light on the fundamental nature of neutrinos.

nucl-ex

Island of Inversion in neutron-rich cobalt isotopes revealed from mass measurements

Mass measurements of the ground and isomeric states of $^{68-70}$Co have been performed using the JYFLTRAP Penning-trap mass spectrometer at the IGISOL facility. The masses were measured, either for the first time for the isomeric states of $^{68}$Co and $^{70}$Co, or with greatly improved precision for the others, removing ambiguities in the mass surface beyond $N=40$. The ordering of the low and high-spin states in $^{68}$Co and $^{70}$Co has also been established. The results, supported by Large-Scale Shell Model and Discrete Non-Orthogonal Shell-Model calculations, show a gradual lowering of intruder states with increasing neutron number, eventually leading to an inversion in $^{70}$Co. These findings clarify previously proposed contradictory interpretations. Finally, we demonstrate the importance of including induced effective 3N forces for a consistent description of binding energies in the island of inversion near $N=40$.

nucl-ex