Magnetic induction tomography using an all-optical $^{87}$Rb atomic magnetometer
Abstract
We demonstrate Magnetic Induction Tomography (MIT) with an all-optical atomic magnetometer. Our instrument creates a conductivity map of conductive objects. Both shape and size of the imaged samples compare very well with the actual shape and size. Given the potential of all-optical atomic magnetometers for miniaturization and extreme sensitivity, the proof-of-principle presented here opens up promising avenues in the development of instrumentation for magnetic induction tomography.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Arne Wickenbrock, Sarunas Jurgilas, Albert Dow, Luca Marmugi, Ferruccio Renzoni. 2014-11-02. Magnetic induction tomography using an all-optical $^{87}$Rb atomic magnetometer. https://doi.org/10.1364/ol.39.006367