arXiv · 1311.6769
Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation
Abstract
We describe the construction and operation of an x-ray beam size monitor (xBSM), a device measuring $e^+$ and $e^-$ beam sizes in the CESR-TA storage ring using synchrotron radiation. The device can measure vertical beam sizes of $10-100~\mu$m on a turn-by-turn, bunch-by-bunch basis at $e^\pm$ beam energies of $\sim2~$GeV. At such beam energies the xBSM images x-rays of $\epsilon\approx$1-10$~$keV ($\lambda\approx 0.1-1$ nm) that emerge from a hard-bend magnet through a single- or multiple-slit (coded aperture) optical element onto an array of 32 InGaAs photodiodes with 50$~\mu$m pitch. Beamlines and detectors are entirely in-vacuum, enabling single-shot beam size measurement down to below 0.1$~$mA ($2.5\times10^9$ particles) per bunch and inter-bunch spacing of as little as 4$~$ns. At $E_{\rm b}=2.1 $GeV, systematic precision of $\sim 1~\mu$m is achieved for a beam size of $\sim12~\mu$m; this is expected to scale as $\propto 1/\sigma_{\rm b}$ and $\propto 1/E_{\rm b}$. Achieving this precision requires comprehensive alignment and calibration of the detector, optical elements, and x-ray beam. Data from the xBSM have been used to extract characteristics of beam oscillations on long and short timescales, and to make detailed studies of low-emittance tuning, intra-beam scattering, electron cloud effects, and multi-bunch instabilities.
Explore related subjects
Keep this discovery
J. P. Alexander, A. Chatterjee, C. Conolly, E. Edwards, M. P. Ehrlichman, E. Fontes, B. K. Heltsley, W. Hopkins, A. Lyndaker, D. P. Peterson, N. T. Rider, D. L. Rubin, J. Savino, R. Seeley, J. Shanks, J. W. Flanagan. 2013-11-26. Vertical beam size measurement in the CESR-TA $e^+e^-$ storage ring using x-rays from synchrotron radiation. https://doi.org/10.1016/j.nima.2014.02.040
Cite the original work for its findings. Save a collection to share your selection of sources.