Abstract
We present an initial test of a new type of a pre-bunched beam pumped free electron maser based on Stimulated Coherent Diffraction Radiation (SCDR) generated in an open resonator. An ultra-fast Schottky Barrier Diode (time response $<1\,$ns) has enabled to investigate the properties of the radiation stored in the cavity as well as the intrinsic properties of the cavity itself. We observed a turn-by-turn SCDR generated by a multibunch beam. When the cavity length was exactly a half of the bunch spacing a clear resonance was observed. Moreover, turn-by-turn measurements revealed the cavity quality factor of $72.88$, which was rather high for an open resonator in the wavelength range of $3-5\,$mm. An exponential growth of the photon intensity as a function of the number of bunches was also demonstrated.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
A. Aryshev, S. Araki, M. Fukuda, N. Terunuma, J. Urakawa, P. Karataev, G. Naumenko, A. Potylitsyn, L. Sukhikh, D. Verigin, K. Sakaue. 2013-10-29. Observation of the Stimulated Coherent Diffraction Radiation in an Open Resonator at LUCX Facility. https://doi.org/10.1016/j.nima.2014.06.056