arXiv · 1203.5672
Signal injection and averaging for position estimation of Permanent-Magnet Synchronous Motors
Abstract
Sensorless control of Permanent-Magnet Synchronous Motors at low velocity remains a challenging task. A now well-established method consists in injecting a high-frequency signal and use the rotor saliency, both geometric and magnetic-saturation induced. This paper proposes a clear and original analysis based on second-order averaging of how to recover the position information from signal injection; this analysis blends well with a general model of magnetic saturation. It also experimentally demonstrates the relevance for position estimation of a simple parametric saturation model recently introduced by the authors.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
Al Kassem Jebai, François Malrait, Philippe Martin, Pierre Rouchon. 2012-03-26. Signal injection and averaging for position estimation of Permanent-Magnet Synchronous Motors. https://arxiv.org/abs/1203.5672