arXiv · 1001.0140
Thermal Control of a Dual Mode Parametric Sapphire Transducer
Abstract
We propose a method to control the thermal stability of a sapphire dielectric transducer made with two dielectric disks separated by a thin gap and resonating in the whispering gallery (WG) modes of the electromagnetic field. The simultaneous measurement of the frequencies of both a WGH mode and a WGE mode allows one to discriminate the frequency shifts due to gap variations from those due to temperature instability. A simple model, valid in quasi equilibrium conditions, describes the frequency shift of the two modes in terms of four tuning parameters. A procedure for the direct measurement of them is presented.
Explore related subjects
Keep this discovery
Jacopo Belfi, Nicolò Beverini, Andrea De Michele, Gianluca Gabbriellini, Francesco Mango, Roberto Passaquieti. 2009-12-31. Thermal Control of a Dual Mode Parametric Sapphire Transducer. https://arxiv.org/abs/1001.0140
Cite the original work for its findings. Save a collection to share your selection of sources.