arXiv ScienceSearch

arXiv · 0911.1033

Fiber-Optic-Gyroscope Measurements Close to Rotating Liquid Helium

Abstract

We previously reported anomalous fiber-optic gyroscope signals observed above rotating rings at temperatures close to liquid helium. Our results suggested that the liquid helium itself may be the source of our observed phenomenon. We constructed a new cryostat experiment that allows rotating a large quantity of liquid helium together with a superconducting niobium tube. The facility is built in such a way that our gyroscope can be placed directly in the center of rotation along the axis; however, the cryostat is built around the gyroscope to allow measuring without interference of helium liquid or gas. An anomalous signal was found of similar value compared to our previous measurements with a changed sign. As this measurement was done at a different location (center position) with respect to our old setup (top position), first hints for a possible field distribution of this phenomenon can be made. However, due to lower angular velocities used in this new setup so far, our measurement resolution was close to three times the resolution of our gyroscope and hence our data represent work in progress.

Explore related subjects

Keep this discovery

BibTeXRIS

M. Tajmar, F. Plesescu. 2009-11-05. Fiber-Optic-Gyroscope Measurements Close to Rotating Liquid Helium. https://doi.org/10.1063/1.3326250

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Electrovacuum Black Hole Uniqueness

We prove the black hole uniqueness conjecture in the axially symmetric, stationary, electrovacuum setting, subject to the refined asymptotic analysis of the associated singular harmonic maps, which includes an analyticity hypothesis at the axes. More precisely, it is shown that any asymptotically flat solution of the Einstein--Maxwell equations in this class, with more than one black hole horizon component is either: Majumdar--Papapetrou, up to a duality rotation, in which case all logarithmic angle defects vanish, or every finite axis rod logarithmic angle defect is strictly negative and hence every interaction force is strictly attractive. The proof extends the singular harmonic map method used for vacuum Kerr uniqueness in [18].

gr-qc

Constraining Modified Mass-to-Horizon Cosmology Through Primordial Inflationary Observables

We investigate slow-roll inflation in a modified cosmological framework inspired by a generalized mass-to-horizon relation (MHR), $M=\gamma {c^2 L^n}/{G}$, where $n$ is a real parameter and $\gamma$ a dimensional constant. Using Padmanabhan's emergence paradigm, we derive the modified Friedmann equations for a flat FRW universe and analyze the dynamics of a canonical scalar field (inflaton) under the slow-roll approximation. We study the resulting inflationary phenomenology for power-law and Starobinsky potentials. For power-law potentials, the MHR modification fails to reconcile these models with current CMB constraints on $r$ and $n_s$. In contrast, Starobinsky inflation exhibits significant sensitivity to deviations from $n=1$. A perturbative analysis ($n=1+\Delta$) yields corrections to inflationary observables. We observe that the scalar power-spectrum normalization, under a fixed-Starobinsky prescription, imposes the stringent constraint $0.960 \lesssim n \lesssim 1.040$ for $N=60$ efolds. This is considerably tighter than spectral-index bounds. Our results establish inflation, particularly Starobinsky-like models, as a sensitive probe of generalized horizon thermodynamics and departures from standard MHR scaling.

gr-qc

Improving the Sensitivity of Gravitational Wave Detection with Weighted Conformal Prediction

In the last decade, kilometre-scale interferometric gravitational-wave detectors have observed hundreds of compact binary mergers, the majority of which are binary black holes. However, the data are noise-dominated, and multiple independent search algorithms (pipelines) are used to enhance sensitivity and improve robustness. Rather than the standard approach of selecting the most significant pipeline output, we combine the outputs from all pipelines using a conformal prediction-based framework to provide statistically rigorous confidence estimates for candidate events. While combining pipelines improves sensitivity and ranking robustness, it requires a principled statistical framework that remains valid as data properties evolve across observing runs. A key challenge is distribution shifts between simulated datasets used for training and calibration and the real, unlabelled, observations used for testing, which can invalidate coverage guarantees and bias confidence estimates. In this work, we address this challenge by incorporating likelihood-ratio reweighting into our conformal prediction framework to account for covariate shift. Using mock datasets containing simulated signals, we demonstrate that weighted conformal prediction restores well-calibrated coverage under covariate shift and increases the confidence of events near the detection threshold, recovering true signals that would otherwise be missed.

gr-qc