Two-stage high frequency pulse tube cooler for refrigeration at 25 K
Abstract
A two-stage Stirling-type U-shape pulse tube cryocooler driven by a 10 kW-class linear compressor was designed, built and tested. A special feature of the cold head is the absence of a heat exchanger at the cold end of the first stage, since the intended application requires no cooling power at this intermediate temperature. Simulations where done using Sage-software to find optimum operating conditions and cold head geometry. Flow-impedance matching was required to connect the compressor designed for 60 Hz operation to the 40 Hz cold head. A cooling power of 12.9 W at 25 K with an electrical input power of 4.6 kW has been achieved up to now. The lowest temperature reached is 13.7 K.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
M. Dietrich, G. Thummes. 2009-12-17. Two-stage high frequency pulse tube cooler for refrigeration at 25 K. https://doi.org/10.1016/j.cryogenics.2010.01.010