arXiv · 0910.0818
A Tungsten / Scintillating Fiber Electromagnetic Calorimeter Prototype for a High-Rate Muon g-2 Experiment
Abstract
A compact and fast electromagnetic calorimeter prototype was designed, built, and tested in preparation for a next-generation, high-rate muon g-2 experiment. It uses a simple assembly procedure: alternating layers of 0.5-mm-thick tungsten plates and 0.5-mm-diameter plastic scintillating fiber ribbons. This geometry leads to a detector having a calculated radiation length of 0.69 cm, a Moliere radius of 1.73 cm, and a measured intrinsic sampling resolution term of (11.8\pm1.1)/\sqrt{E(GeV)}, in the range 1.5 to 3.5 GeV. The construction procedure, test beam results, and GEANT-4 comparative simulations are described.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
R. McNabb, J. Blackburn, J. D. Crnkovic, D. W. Hertzog, B. Kiburg, J. Kunkle, E. Thorsland, D. M. Webber, K. R. Lynch. 2009-10-05. A Tungsten / Scintillating Fiber Electromagnetic Calorimeter Prototype for a High-Rate Muon g-2 Experiment. https://doi.org/10.1016/j.nima.2009.01.007
Cite the original work for its findings. Save a collection to share your selection of sources.