arXiv Science⌕ Search

arXiv · 0904.3162

UNICS - An Unified Instrument Control System for Small/Medium Sized Astronomical Observatories

Abstract

Although the astronomy community is witnessing an era of large telescopes, smaller and medium sized telescopes still maintain their utility being larger in numbers. In order to obtain better scientific outputs it is necessary to incorporate modern and advanced technologies to the back-end instruments and to their interfaces with the telescopes through various control processes. However often tight financial constraints on the smaller and medium size observatories limit the scope and utility of these systems. Most of the time for every new development on the telescope the back-end control systems are required to be built from scratch leading to high costs and efforts. Therefore a simple, low cost control system for small and medium size observatory needs to be developed to minimize the cost and efforts while going for the expansion of the observatory. Here we report on the development of a modern, multipurpose instrument control system UNICS (Unified Instrument Control System) to integrate the controls of various instruments and devices mounted on the telescope. UNICS consists of an embedded hardware unit called Common Control Unit (CCU) and Linux based data acquisition and User Interface. The Hardware of the CCU is built around the Atmel make ATmega 128 micro-controller and is designed with a back-plane, Master Slave architecture. The Graphical User Interface (GUI) has been developed based on QT and the back end application software is based on C/C++. UNICS provides feedback mechanisms which give the operator a good visibility and a quick-look display of the status and modes of instruments. UNICS is being used for regular science observations since March 2008 on 2m, f/10 IUCAA Telescope located at Girawali, Pune India.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Mudit K. Srivastava, A. N. Ramaprakash, Mahesh P. Burse, Pravin A. Chordia, Kalpesh S. Chillal, Vilas B. Mestry, Hillol K. Das, Abhay A. Kohok. 2009-04-21. UNICS - An Unified Instrument Control System for Small/Medium Sized Astronomical Observatories. https://doi.org/10.1086/644648

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Reconstruction of cosmic-ray direction and energy in radio arrays using deep ensemble graph neural networks

Using advanced machine learning techniques, we developed a method to reconstruct the arrival direction and energy of ultra-high-energy cosmic rays from the voltage traces they induce on ground-based radio detector arrays. In our approach, triggered antennas are represented as a graph structure, which serves as input for a graph neural network (GNN). By incorporating physical knowledge into both the GNN architecture and the input data, we improve the precision and reduce the required size of the training set with respect to a fully data-driven approach. This method achieves an angular resolution of 0.092 degrees and an electromagnetic energy reconstruction resolution of 16.4% on simulated data with realistic noise conditions. We also employ uncertainty estimation methods to enhance the reliability of our predictions, quantifying the confidence of the GNN's outputs and providing confidence intervals for both direction and energy reconstruction. Finally, we investigate strategies to verify the model's consistency and robustness under real-life variations, with the goal of identifying scenarios in which predictions remain reliable despite domain shifts between simulation and reality.

astro-ph.IM↗

Hybrid neural denoising for resource-efficient near- and sub-threshold radio triggering of extensive air showers

Autonomous radio self-triggering for extensive air showers requires strong rejection of radio-frequency interference while preserving weak pulses within station-level hardware constraints. We present a hybrid neural trigger comprising a compact waveform denoiser followed by a classifier. The method is evaluated using experimentally measured high-interference background traces and detector-folded simulated air-shower pulses produced with the Pierre Auger Offline chain, with the benchmark concentrated in the near-threshold regime. Hardware constraints are incorporated through hyperparameter optimisation, quantisation-aware training, and high-granularity fixed-point quantisation. Applying the conventional peak-envelope trigger after denoising increases its area under the receiver-operating-characteristic curve from 0.63 to 0.98. At a false-positive rate of 10^-4, the full denoiser-classifier chain retains about 41% of the held-out signal traces, compared with 27% for the classifier acting on the raw waveform and about 2% for the peak-envelope reference. The fixed-point firmware is synthesised, placed, and routed on representative field-programmable gate array targets, where it achieves timing closure with microsecond-scale latency and compact arithmetic-resource usage. These results establish hybrid neural denoising as a practical FPGA-compatible route toward radio-only triggering of weak and inclined air-shower signals in noisy environments.

astro-ph.IM↗

Characterization of the RF Board for microwave SQUID multiplexing readout electronics

Microwave SQUID multiplexing ($μ$MUX) is a widely used readout technique for large-scale transition-edge sensor (TES) arrays. It uses radio-frequency (RF) probe tones to interrogate cryogenic resonators, requiring frequency conversion between the baseband electronics and the cryogenic RF signal chain. This work describes the RF Board, a room-temperature frequency-conversion board deployed in the AliCPT $μ$MUX readout system. The board up-converts 0-4 GHz baseband I/Q signals to the 4-8 GHz RF band for injection into the cryogenic chain and down-converts returned RF signals to baseband I/Q for ADC digitization. For the current 1000-tone operation, with a DAC output tone power of -30 dBm/tone, the required power windows are -35 to -25 dBm/tone for the RF tones transmitted to the cryostat and -45 to -35 dBm/tone at the ADC input for the returned tones. The RF Board is characterized using swept single-tone measurements covering up-conversion, down-conversion, and RF loopback. Based on these measurements, the RF output power is calculated to be -31.06 to -25.53 dBm, satisfying the RF output window. Assuming a representative cryogenic-chain transmission of -40 dB, the loopback result gives an estimated returned power of -45 to -35 dBm, within the target range. These results show that the RF Board meets the wideband frequency-conversion and tone-power requirements for the $μ$MUX readout system.

astro-ph.IM↗