Summary of ILD performance at SPS1a'
Abstract
The performance of the ILD detector at the ILC for the analysis of $μ$ and $τ$ channels at the SUSY benchmark-point SPS1a' has been studied with full detector simulation. It is concluded that if 500 fb$^{-1}$ is delivered to the experiment, $Δ(\MXN{1}) = 920 \MeVcc$, $Δ(\msmul) = 100 \MeVcc$, $Δ(\MXN{2}) = 1.38 ~\GeVcc$, and $Δ(σ(\eeto \smul \smul))$ = 1.35 fb can be achieved from the $μ$ channels alone. The preliminary results from the $\stau$ channels, indicates that $Δ(P_τ) = 13 $ % is also achievable.
Explore related subjects
Keep this discovery
Mikael Berggren, Nicola d'Ascenzo, Peter Schade, Olga Stempel. 2009-02-14. Summary of ILD performance at SPS1a'. https://arxiv.org/abs/0902.2434