In an optical configuration consisting of a flat plate of vacuum between upper and lower spaces of uniform dielectric regions of n>1, we have calculated two output light intensities for two input lights from the Maxwell's equations as functions of the incision angle, a light intensity ratio, a phase difference of the two input lights, and a thickness of the vacuum layer, where the two input lights come from upper and lower dielectric regions with the same incision angles, and one of the output light goes into upper dielectric and the other goes into lower dielectric. We have found that, when evanescent lights exist at the upper and lower boundary and interfere each other, there is one set of incision angles and phase differences for any combination of an input light ratio and a thickness of the vacuum layer where one of output lights becomes zero. This finding will possibly lead to an innovative optical switch with which an optical output light can be switched on and off with a control light with an intensity much lower than that of the output light.

Explore related subjects

Keep this discovery

BibTeXRIS

Naofumi Kitsunezaki, Jun-ichi Mizusawa, Akio Kitsunezaki. 2009-01-10. A Theoretical Study on an Optical Switch Using Interfered Evanescent Light. https://arxiv.org/abs/0901.1362

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

Two-step high-accuracy microwave frequency measurement and time-frequency analysis based on optical frequency combs

Broadband microwave frequency measurement and time-frequency analysis are crucial for applications such as electronic warfare. However, when it comes to ultra wideband signal analysis, traditional electronic methods have high analysis accuracy, but intrinsic electronic bottlenecks limit their real-time analysis. Here, we propose and experimentally demonstrate a two-step microwave frequency measurement and time-frequency analysis method based on optical frequency combs. The system first performs coarse frequency localization over the 0-40 GHz range using stimulated-Brillouin-scattering-assisted frequency-to-time mapping (FTTM) and dual-comb channelized reception. The dual-comb is then reapplied for downconverting the signal under test, followed by digital signal processing to achieve high-accuracy unambiguous frequency extraction. Experimental results show that the system achieves mean single-tone frequency measurement errors of less than 10 kHz over 0-40 GHz. We further experimentally measure multi-tone, linearly frequency-modulated, and V-shaped frequency-modulated signals, demonstrating the proposed method's capability for analyzing complex signals.

physics.optics

A Two-Mirror Faceted Projection System for EUV Lithography

We propose an all-reflective two-mirror projection system for extreme ultraviolet (EUV) lithography operating at exposure wavelengths of $13.5$~nm (Mo/Si) and $11.2$~nm (Ru/Be), delivering a fourfold ($4\times$) demagnification of the periodic mask pattern at a numerical aperture approaching unity ($\mathrm{NA}_{\max} \approx 0.993$). In contrast to conventional EUV projection objectives that incorporate 6--10 aspheric mirrors with an overall optical throughput of less than $15\%$, the proposed design redirects each accepted discrete spatial diffraction order scattered by the mask onto the wafer via a dedicated pair of planar mirror facets. The number of reflections is strictly fixed at two for all accepted orders, retaining $50$--$60\%$ of the power leaving the mask in each accepted order. We derive a spatial geometry providing rigorous optical path length equalization across all diffraction orders, thereby removing order-dependent propagation phase shifts. Individually optimized 30-bilayer Bragg multilayer coatings are designed for each facet using the transfer matrix method combined with global evolutionary optimization algorithms. The architecture is generalized to a three-dimensional vector formulation with a two-dimensionally periodic mask. Utilizing inverse lithography technology, Fourier parameterization, and a differentiable electromagnetic modal waveguide solver, we solve the synthesis problem for binary absorber masks (La absorber on a Ru/Be/Sr multilayer mirror). We demonstrate simulated aerial images of sub-10-nm features on the wafer (isolated peaks with a full width at half maximum (FWHM) of approximately $5.4$~nm and line pairs with a critical dimension of $6$~nm) and find that the two peaks remain resolved for the tested wafer defocus values from $0$ to $5$~nm along the $z$-axis.

physics.optics

Antimony for broadband nanophotonics across the ultraviolet, visible and infrared

Semimetal elemental antimony (Sb) nanostructures show great potential for applications where nanophotonic properties play a key role, such as phase-change optical memories, non-linear optical elements, photothermal therapy agents, photodetectors and photocatalysts. However, designing advanced Sb-based photonic devices critically requires an accurate and reliable knowledge of the optical response of bulk and nanoscale Sb. Herein, we report for the first time a fully consistent and accurately measured dielectric function for Sb nanoscale films in a wide spectral range from the ultraviolet to the far infrared (4 - 0.04 eV, i.e. ~ 0.3 - 30 $\mu$m), surpassing previous reports that explored a limited spectral range. It is found that the Sb spectral response is driven exclusively by giant interband transitions in the visible up to mid infrared (4 - 0.4 eV, i.e. ~ 0.3 - 3 $\mu$m), and that their contribution dominates over that of free carriers down to 0.12 eV (i.e. ~ 10 $\mu$m). Such spectral response enables Sb nanostructures to display spectrally selective and tunable nanophotonic resonances. First, we showcase interband plasmonic resonances in the visible-to-near infrared for Sb nanogratings. Second, we report giant refractive index dielectric resonances in the mid infrared for nanostructured Sb/dielectric/metal resonant cavities. These findings open a pathway to optimized planar Sb nanoscale designs enabling a tailored light-matter interaction, which will be useful for integrated data, telecom, medical, optoelectronic and energy conversion devices operating in a broad spectral range.

physics.optics