arXiv ScienceSearch

arXiv · 0812.4951

High Accuracy Near-infrared Imaging Polarimetry with NICMOS

Abstract

The findings of a nine orbit calibration plan carried out during HST Cycle 15, to fully determine the NICMOS camera 2 (2.0 micron) polarization calibration to high accuracy, are reported. Recently Ueta et al. and Batcheldor et al. have suggested that NICMOS possesses a residual instrumental polarization at a level of 1.2-1.5%. This would completely inhibit the data reduction in a number of GO programs, and hamper the ability of the instrument to perform high accuracy polarimetry. We obtained polarimetric calibration observations of three polarimetric standards at three spacecraft roll angles separated by ~60deg. Combined with archival data, these observations were used to characterize the residual instrumental polarization in order for NICMOS to reach its full potential of accurate imaging polarimetry at p~1%. Using these data, we place an 0.6% upper limit on the instrumental polarization and calculate values of the parallel transmission coefficients that reproduce the ground-based results for the polarimetric standards. The uncertainties associated with the parallel transmission coefficients, a result of the photometric repeatability of the observations, are seen to dominate the accuracy of p and theta. However, the updated coefficients do allow imaging polarimetry of targets with p~1.0% at an accuracy of +/-0.6% and +/-15deg. This work enables a new caliber of science with HST.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D. Batcheldor, G. Schneider, D. C. Hines, G. D. Schmidt, D. J. Axon, A. Robinson, W. Sparks, C. Tadhunter. 2008-12-29. High Accuracy Near-infrared Imaging Polarimetry with NICMOS. https://doi.org/10.1086/597197

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

On binary pulsars and the force of gravity

The energy-momentum budget of the astrophysical systems can be studied by the exact local conservation equation derived by Landau and Lifshitz. We show that a similar equation is valid for the Einstein-Cartan gravity. We reanalyze a binary pulsar system using the Landau-Lifshitz conservation equation and show that the orbital period change rate can be completely understood as a curvature backreaction process. Taking into account the detailed theoretical and observational research of relativistic binary pulsar systems, especially the system of Hulse and Taylor, we conclude that general relativity and astrophysical observations rule out the existence of gravitational radiation. We comment upon the LIGO GW events and their alternative explanation, as well as the recent pulsar timing arrays data.

astro-ph

Oscillation frequencies and mode lifetimes in alpha Centauri A

We analyse our recently-published velocity measurements of alpha Cen A (Butler et al. 2004). After adjusting the weights on a night-by-night basis in order to optimize the window function to minimize sidelobes, we extract 42 oscillation frequencies with l=0 to 3 and measure the large and small frequency separations. We give fitted relations to these frequencies that can be compared with theoretical models and conclude that the observed scatter about these fits is due to the finite lifetimes of the oscillation modes. We estimate the mode lifetimes to be 1-2 d, substantially shorter than in the Sun.

astro-ph

Hipparcos period-luminosity relations for Miras and semiregular variables

We present period-luminosity diagrams for nearby Miras and semiregulars, selecting stars with parallaxes better than 20 per cent and well-determined periods. Using K-band magnitudes, we find two well-defined P-L sequences, one corresponding to the standard Mira P-L relation and the second shifted to shorter periods by a factor of about 1.9. The second sequence only contains semiregular variables, while the Mira sequence contains both Miras and semiregulars. Several semiregular stars show double periods in agreement with both relations. The Whitelock evolutionary track is shown to fit the data, indicating that the semiregulars are Mira progenitors. The transition between the two sequences may correspond to a change in pulsation mode or to a change in the stellar structure. Large amplitude pulsations leading to classical Mira classification occur mainly near the tip of the local AGB luminosity function.

astro-ph