arXiv ScienceSearch

arXiv · 0806.1666

XPOL - the correlation polarimeter at the IRAM 30m telescope

Abstract

XPOL, the first correlation polarimeter at a large millimeter telescope, uses a flexible digital correlator to measure all four Stokes parameters simultaneously, i.e. the total power I, the linear polarization components Q and U, and the circular polarization V. The versatility of the backend provides adequate bandwidth for efficient continuum observations as well as sufficient spectral resolution (40 kHz) for observations of narrow lines. We demonstrate that the polarimetry specific calibrations are handled with sufficient precision, in particular the relative phase between the Observatory's two orthogonally linearly polarized receivers. The many facets of instrumental polarization are studied at 3mm wavelength in all Stokes parameters: on-axis with point sources and off-axis with beam maps. Stokes Q which is measured as the power difference between the receivers is affected by instrumental polarization at the 1.5% level. Stokes U and V which are measured as cross correlations are very little affected (maximum sidelobes 0.6% (U) and 0.3% (V)). These levels critically depend on the precision of the receiver alignment. They reach these minimum levels set by small ellipticities of the feed horns when alignment is optimum (<~ 0.3"). A second critical prerequisite for low polarization sidelobes turned out to be the correct orientation of the polarization splitter grid. Its cross polarization properties are modeled in detail. XPOL observations are therefore limited only by receiver noise in Stokes U and V even for extended sources. Systematic effects set in at the 1.5% level in observations of Stokes Q. With proper precautions, this limitation can be overcome for point sources. Stokes Q observations of extended sources are the most difficult with XPOL.

Explore related subjects

Keep this discovery

BibTeXRIS

Clemens Thum, Helmut Wiesemeyer, Gabriel Paubert, Santiago Navarro, David Morris. 2008-06-10. XPOL - the correlation polarimeter at the IRAM 30m telescope. https://doi.org/10.1086/590190

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

HX-POL - A Balloon-Borne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

astro-ph

Quintessence models with an oscillating equation of state and their potentials

In this paper, we investigate the quintessence models with an oscillating equation of state (EoS) and their potentials. From the constructed potentials, which have the EoS of $ω_ϕ=ω_0+ω_1\sin z$, we find they are all the oscillating functions of the field $ϕ$, and the oscillating amplitudes are decreasing (or increasing) with $ϕ$. From the evolutive equation of the field $ϕ$, we find this is caused by the expansion of the universe. This also makes that it is very difficult to build a model whose EoS oscillates forever. However one can build a model with EoS oscillating for a period. Then we discuss three quintessence models, which are the combinations of the invert power law functions and the oscillating functions of the field $ϕ$. We find they all follow the oscillating EoS.

astro-ph

Is "Spike" a Reliable Feature in Porb Distribution of AM HER Stars?

Orbital periods in AM Her stars (polars) are synchronized with spin periods of white dwarf by its high magnetic field. Since the last study of Porb distribution of these systems, the number of known objects of such type has more than doubled. This challenged us to compile a new updated catalogue of cataclysmic variables with highly magnetic white dwarfs (polars) and to study their Porb distribution. In this paper we also discus if "spike" is reliable feature in the distribution. ("Spike" is a concentration of polars in the distribution of their orbital periods near Porb = 114 min and was previously discussed by Ritter & Kolb (1992) and Shahbaz & Wood (1996).)

astro-ph