arXiv ScienceSearch

arXiv · 0704.2196

Absolute Calibration and Characterization of the Multiband Imaging Photometer for Spitzer. II. 70 micron Imaging

Abstract

The absolute calibration and characterization of the Multiband Imaging Photometer for Spitzer (MIPS) 70 micron coarse- and fine-scale imaging modes are presented based on over 2.5 years of observations. Accurate photometry (especially for faint sources) requires two simple processing steps beyond the standard data reduction to remove long-term detector transients. Point spread function (PSF) fitting photometry is found to give more accurate flux densities than aperture photometry. Based on the PSF fitting photometry, the calibration factor shows no strong trend with flux density, background, spectral type, exposure time, or time since anneals. The coarse-scale calibration sample includes observations of stars with flux densities from 22 mJy to 17 Jy, on backgrounds from 4 to 26 MJy sr^-1, and with spectral types from B to M. The coarse-scale calibration is 702 +/- 35 MJy sr^-1 MIPS70^-1 (5% uncertainty) and is based on measurements of 66 stars. The instrumental units of the MIPS 70 micron coarse- and fine-scale imaging modes are called MIPS70 and MIPS70F, respectively. The photometric repeatability is calculated to be 4.5% from two stars measured during every MIPS campaign and includes variations on all time scales probed. The preliminary fine-scale calibration factor is 2894 +/- 294 MJy sr^-1 MIPS70F^-1 (10% uncertainty) based on 10 stars. The uncertainty in the coarse- and fine-scale calibration factors are dominated by the 4.5% photometric repeatability and the small sample size, respectively. The 5-sigma, 500 s sensitivity of the coarse-scale observations is 6-8 mJy. This work shows that the MIPS 70 micron array produces accurate, well calibrated photometry and validates the MIPS 70 micron operating strategy, especially the use of frequent stimulator flashes to track the changing responsivities of the Ge:Ga detectors.

Explore related subjects

Keep this discovery

BibTeXRIS

Karl D. Gordon, Charles W. Engelbracht, Dario Fadda, John Stansberry, Stefanie Wachter, Dave T. Frayer, George Rieke, Alberto Noriega-Crespo, William B. Latter, Erick Young, Gerry Neugebauer, Zoltan Balog, Herve Dole, Eiichi Egami, Dean Hines, Doug Kelly, Francine Marleau, Karl Misselt, Jane Morrison, Pablo Perez-Gonzalez, Jeonghee Rho, Wm. A. Wheaton. 2007-04-17. Absolute Calibration and Characterization of the Multiband Imaging Photometer for Spitzer. II. 70 micron Imaging. https://doi.org/10.1086/522675

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related papers

HX-POL - A Balloon-Borne Hard X-Ray Polarimeter

We report on the design and estimated performance of a balloon-borne hard X-ray polarimeter called HX-POL. The experiment uses a combination of Si and Cadmium Zinc Telluride detectors to measure the polarization of 50 keV-400 keV X-rays from cosmic sources through the dependence of the angular distribution of Compton scattered photons on the polarization direction. On a one-day balloon flight, HX-POL would allow us to measure the polarization of bright Crab-like sources for polarization degrees well below 10%. On a longer (15-30 day) flight from Australia or Antarctica, HX-POL would be be able to measure the polarization of bright galactic X-ray sources down to polarization degrees of a few percent. Hard X-ray polarization measurements provide unique venues for the study of particle acceleration processes by compact objects and relativistic outflows. In this paper, we discuss the overall instrument design and performance. Furthermore, we present results from laboratory tests of the Si and CZT detectors.

astro-ph

Quintessence models with an oscillating equation of state and their potentials

In this paper, we investigate the quintessence models with an oscillating equation of state (EoS) and their potentials. From the constructed potentials, which have the EoS of $ω_ϕ=ω_0+ω_1\sin z$, we find they are all the oscillating functions of the field $ϕ$, and the oscillating amplitudes are decreasing (or increasing) with $ϕ$. From the evolutive equation of the field $ϕ$, we find this is caused by the expansion of the universe. This also makes that it is very difficult to build a model whose EoS oscillates forever. However one can build a model with EoS oscillating for a period. Then we discuss three quintessence models, which are the combinations of the invert power law functions and the oscillating functions of the field $ϕ$. We find they all follow the oscillating EoS.

astro-ph

Is "Spike" a Reliable Feature in Porb Distribution of AM HER Stars?

Orbital periods in AM Her stars (polars) are synchronized with spin periods of white dwarf by its high magnetic field. Since the last study of Porb distribution of these systems, the number of known objects of such type has more than doubled. This challenged us to compile a new updated catalogue of cataclysmic variables with highly magnetic white dwarfs (polars) and to study their Porb distribution. In this paper we also discus if "spike" is reliable feature in the distribution. ("Spike" is a concentration of polars in the distribution of their orbital periods near Porb = 114 min and was previously discussed by Ritter & Kolb (1992) and Shahbaz & Wood (1996).)

astro-ph